Lines Matching refs:be

37     description: boolean, regulator should never be disabled
45 This property is intended to only be used for regulators where
54 description: allow the regulator performance level to be configured
59 disabling ramp rate, it should be explicitly initialised to zero (regulator-ramp-delay
101 for the regulator at run-time. Elements may be specified in any order.
122 hardware performs emergency shutdown. Zero can be passed to disable
123 protection and value '1' indicates that protection should be enabled but
124 limit setting can be omitted.
129 Zero can be passed to disable error detection and value '1' indicates
130 that detection should be enabled but limit setting can be omitted.
134 is assumed still to be functional but approaching limit where it gets
135 damaged. Recovery actions should be initiated. Zero can be passed to
137 be enabled but limit setting can be omitted.
141 hardware performs emergency shutdown. Zero can be passed to disable
142 protection and value '1' indicates that protection should be enabled but
143 limit setting can be omitted. Limit is given as microvolt offset from
149 Zero can be passed to disable error detection and value '1' indicates
150 that detection should be enabled but limit setting can be omitted. Limit
155 is assumed still to be functional but approaching limit where it gets
156 damaged. Recovery actions should be initiated. Zero can be passed to
158 be enabled but limit setting can be omitted. Limit is given as microvolt
163 hardware performs emergency shutdown. Zero can be passed to disable
164 protection and value '1' indicates that protection should be enabled but
165 limit setting can be omitted. Limit is given as microvolt offset from
171 Zero can be passed to disable error detection and value '1' indicates
172 that detection should be enabled but limit setting can be omitted. Limit
177 hardware is assumed still to be functional but approaching limit where
178 it gets damaged. Recovery actions should be initiated. Zero can be passed
180 be enabled but limit setting can be omitted. Limit is given as microvolt
185 hardware performs emergency shutdown. Zero can be passed to disable
186 protection and value '1' indicates that protection should be enabled but
187 limit setting can be omitted.
192 Zero can be passed to disable error detection and value '1' indicates
193 that detection should be enabled but limit setting can be omitted.
197 hardware is assumed still to be functional but approaching limit where it
198 gets damaged. Recovery actions should be initiated. Zero can be passed to
200 be enabled but limit setting can be omitted.
213 is 2-way - all coupled regulators should be linked with each other.
214 A regulator should not be coupled with its supplier.
225 that can be changed safely in a single step.
240 description: regulator should be on in suspend state.
244 description: regulator should be off in suspend state.
248 description: minimum voltage may be set in suspend state.
251 description: maximum voltage may be set in suspend state.
254 description: the default voltage which regulator would be set in
261 in suspend can be changed in runtime.