Lines Matching refs:e_dbg
118 e_dbg("Programming MAC Address into RAR[0]\n"); in e1000e_init_rx_addrs()
123 e_dbg("Clearing RAR[1-%u]\n", rar_count - 1); in e1000e_init_rx_addrs()
158 e_dbg("NVM Read Error\n"); in e1000_check_alt_mac_addr_generic()
173 e_dbg("NVM Read Error\n"); in e1000_check_alt_mac_addr_generic()
183 e_dbg("Ignoring Alternate Mac Address with MC bit set\n"); in e1000_check_alt_mac_addr_generic()
443 e_dbg("Error configuring flow control\n"); in e1000e_check_for_copper_link()
485 e_dbg("NOT Rx'ing /C/, disable AutoNeg and force link.\n"); in e1000e_check_for_fiber_link()
498 e_dbg("Error configuring flow control\n"); in e1000e_check_for_fiber_link()
507 e_dbg("Rx'ing /C/, enable AutoNeg and stop forcing link.\n"); in e1000e_check_for_fiber_link()
548 e_dbg("NOT Rx'ing /C/, disable AutoNeg and force link.\n"); in e1000e_check_for_serdes_link()
561 e_dbg("Error configuring flow control\n"); in e1000e_check_for_serdes_link()
570 e_dbg("Rx'ing /C/, enable AutoNeg and stop forcing link.\n"); in e1000e_check_for_serdes_link()
586 e_dbg("SERDES: Link up - forced.\n"); in e1000e_check_for_serdes_link()
590 e_dbg("SERDES: Link down - force failed.\n"); in e1000e_check_for_serdes_link()
603 e_dbg("SERDES: Link up - autoneg completed successfully.\n"); in e1000e_check_for_serdes_link()
606 e_dbg("SERDES: Link down - invalid codewords detected in autoneg.\n"); in e1000e_check_for_serdes_link()
610 e_dbg("SERDES: Link down - no sync.\n"); in e1000e_check_for_serdes_link()
614 e_dbg("SERDES: Link down - autoneg failed\n"); in e1000e_check_for_serdes_link()
644 e_dbg("NVM Read Error\n"); in e1000_set_default_fc_generic()
692 e_dbg("After fix-ups FlowControl is now = %x\n", hw->fc.current_mode); in e1000e_setup_link_generic()
704 e_dbg("Initializing the Flow Control address, type and timer regs\n"); in e1000e_setup_link_generic()
770 e_dbg("Flow control param set incorrectly\n"); in e1000_commit_fc_settings_generic()
806 e_dbg("Never got a valid link from auto-neg!!!\n"); in e1000_poll_fiber_serdes_link_generic()
815 e_dbg("Error while checking for link\n"); in e1000_poll_fiber_serdes_link_generic()
821 e_dbg("Valid Link Found\n"); in e1000_poll_fiber_serdes_link_generic()
856 e_dbg("Auto-negotiation enabled\n"); in e1000e_setup_fiber_serdes_link()
870 e_dbg("No signal detected\n"); in e1000e_setup_fiber_serdes_link()
964 e_dbg("hw->fc.current_mode = %u\n", hw->fc.current_mode); in e1000e_force_mac_fc()
982 e_dbg("Flow control param set incorrectly\n"); in e1000e_force_mac_fc()
1023 e_dbg("Error forcing flow control settings\n"); in e1000e_config_fc_after_link_up()
1045 e_dbg("Copper PHY and Auto Neg has not completed.\n"); in e1000e_config_fc_after_link_up()
1105 e_dbg("Flow Control = FULL.\n"); in e1000e_config_fc_after_link_up()
1108 e_dbg("Flow Control = Rx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1123 e_dbg("Flow Control = Tx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1137 e_dbg("Flow Control = Rx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1143 e_dbg("Flow Control = NONE.\n"); in e1000e_config_fc_after_link_up()
1152 e_dbg("Error getting link speed and duplex\n"); in e1000e_config_fc_after_link_up()
1164 e_dbg("Error forcing flow control settings\n"); in e1000e_config_fc_after_link_up()
1182 e_dbg("PCS Auto Neg has not completed.\n"); in e1000e_config_fc_after_link_up()
1238 e_dbg("Flow Control = FULL.\n"); in e1000e_config_fc_after_link_up()
1241 e_dbg("Flow Control = Rx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1256 e_dbg("Flow Control = Tx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1270 e_dbg("Flow Control = Rx PAUSE frames only.\n"); in e1000e_config_fc_after_link_up()
1276 e_dbg("Flow Control = NONE.\n"); in e1000e_config_fc_after_link_up()
1288 e_dbg("Error forcing flow control settings\n"); in e1000e_config_fc_after_link_up()
1323 e_dbg("%u Mbps, %s Duplex\n", in e1000e_get_speed_and_duplex_copper()
1371 e_dbg("Driver can't access device - SMBI bit is set.\n"); in e1000e_get_hw_semaphore()
1390 e_dbg("Driver can't access the NVM\n"); in e1000e_get_hw_semaphore()
1430 e_dbg("Auto read by HW from NVM has not completed.\n"); in e1000e_get_auto_rd_done()
1451 e_dbg("NVM Read Error\n"); in e1000e_valid_led_default()
1714 e_dbg("Master requests are pending.\n"); in e1000e_disable_pcie_master()
1732 e_dbg("Not in Adaptive IFS mode!\n"); in e1000e_reset_adaptive()
1758 e_dbg("Not in Adaptive IFS mode!\n"); in e1000e_update_adaptive()