Home
last modified time | relevance | path

Searched refs:panic (Results 1 – 25 of 70) sorted by relevance

123

/xen/xen/arch/arm/platforms/
A Dxgene-storm.c51 panic("%s: Can not find interrupt controller node\n", __func__); in xgene_check_pirq_eoi()
55 panic("%s: Cannot find a valid address for the distributor\n", __func__); in xgene_check_pirq_eoi()
64 panic("OLD X-Gene Firmware is not supported by Xen.\n" in xgene_check_pirq_eoi()
/xen/xen/arch/x86/guest/xen/
A Dxen.c81 panic("unable to reserve shared info memory page\n"); in map_shared_info()
86 panic("failed to map shared_info page: %ld\n", rc); in map_shared_info()
150 panic("failed to allocate PFN usage rangeset\n"); in init_memmap()
160 panic("unable to add RAM to in-use PFN rangeset\n"); in init_memmap()
168 panic("unable to add range [%#lx, %#lx] to in-use PFN rangeset\n", in init_memmap()
311 panic("unable to remap vCPU info and vCPUs > legacy limit\n"); in resume()
A Dpvh-boot.c46 panic("Magic value is wrong: %x\n", pvh_info->magic); in convert_pvh_info()
54 panic("The module array is too small, size %zu, requested %u\n", in convert_pvh_info()
/xen/xen/arch/arm/
A Dgic-v2.c955 panic("GICv2: Cannot remap v2m register frame\n"); in gicv2_add_v2m_frame_to_list()
965 panic("GICv2: Invalid v2m base SPI:%u\n", spi_start); in gicv2_add_v2m_frame_to_list()
974 panic("GICv2: Cannot allocate memory for v2m frame\n"); in gicv2_add_v2m_frame_to_list()
1042 panic("GICv2: Cannot find a valid address for the CPU\n"); in gicv2_dt_init()
1054 panic("GICv2: Cannot find the maintenance IRQ\n"); in gicv2_dt_init()
1229 panic("GICv2: Failed to get MADT table, %s\n", msg); in gicv2_acpi_init()
1237 panic("GICv2: No valid GICC entries exists\n"); in gicv2_acpi_init()
1247 panic("GICv2: No valid GICD entries exists\n"); in gicv2_acpi_init()
1277 panic("GICv2 interfaces not page aligned\n"); in gicv2_init()
1281 panic("GICv2: Failed to ioremap for GIC distributor\n"); in gicv2_init()
[all …]
A Dgic.c255 panic("Unable to find compatible GIC in the device tree\n"); in gic_dt_preinit()
270 panic("No valid GICD entries exists\n"); in gic_acpi_preinit()
275 panic("Unable to find compatible GIC in the ACPI table\n"); in gic_acpi_preinit()
296 panic("Failed to initialize the GIC drivers\n"); in gic_init()
370 panic("Unhandled SGI %d on CPU%d\n", sgi, smp_processor_id()); in do_sgi()
A Dtime.c125 panic("Unable to find a compatible timer in the device tree\n"); in preinit_dt_xen_time()
152 panic("Timer: Cannot initialize platform timer\n"); in preinit_xen_time()
168 panic("Timer: Unable to retrieve IRQ %u from the device tree\n", i); in init_dt_xen_time()
181 panic("CPU does not support the Generic Timer v1 interface\n"); in init_xen_time()
A Dsetup.c309 panic("module %s command line too long\n", name); in add_boot_cmdline()
410 panic("Unable to allocate memory for relocating the Device-Tree.\n"); in relocate_fdt()
600 panic("No memory bank\n"); in setup_mm()
604 panic("AIVIVT instruction cache not supported\n"); in setup_mm()
659 panic("Not not enough space for xenheap\n"); in setup_mm()
806 panic("Invalid device tree blob at physical address %#lx.\n" in start_xen()
929 panic("Couldn't configure correctly all the IOMMUs.\n"); in start_xen()
960 panic("Error creating domain 0\n"); in start_xen()
963 panic("Could not set up DOM0 guest OS\n"); in start_xen()
A Dgic-v3.c893 panic("GICv3: Invalid number of priority bits\n"); in gicv3_hyp_init()
1369 panic("GICv3: Failed to ioremap for GIC distributor\n"); in gicv3_ioremap_distributor()
1380 panic("GICv3: Cannot find a valid distributor address\n"); in gicv3_dt_init()
1398 panic("GICv3: No rdist base found for region %d\n", i); in gicv3_dt_init()
1411 panic("GICv3: Cannot find the maintenance IRQ\n"); in gicv3_dt_init()
1675 panic("GICv3: No valid GICD entries exists\n"); in gicv3_acpi_init()
1687 panic("GICv3: No valid GICR entries exists\n"); in gicv3_acpi_init()
1707 panic("GICv3: Can't get Redistributor entry\n"); in gicv3_acpi_init()
1713 panic("GICv3: No valid GICC entries exists\n"); in gicv3_acpi_init()
1774 panic("GICv3: no distributor detected\n"); in gicv3_init()
[all …]
A Ddomain_build.c136 panic("Failed map pages to DOM0: %d\n", res); in insert_11_bank()
304 panic("Unable to allocate first memory bank\n"); in allocate_memory_11()
476 panic("Failed to allocate requested domain memory." in allocate_memory()
747 panic("Cannot cope with this size\n"); in make_hypervisor_node()
1720 panic("Unsupported GIC version\n"); in make_gic_domU_node()
2252 panic("Cannot find the /chosen node\n"); in initrd_load()
2259 panic("Cannot fix up \"linux,initrd-start\" property\n"); in initrd_load()
2266 panic("Cannot fix up \"linux,initrd-end\" property\n"); in initrd_load()
2270 panic("Unable to map the hwdom initrd\n"); in initrd_load()
2275 panic("Unable to copy the initrd in the hwdom memory\n"); in initrd_load()
[all …]
A Dkernel.c88 panic("Not enough memory in the first bank for the kernel+dtb+initrd\n"); in place_modules()
115 panic("Unable to find suitable location for dtb+initrd\n"); in place_modules()
172 panic("Unable to map the hwdom kernel\n"); in kernel_zimage_load()
177 panic("Unable to copy the kernel in the hwdom memory\n"); in kernel_zimage_load()
A Dbootfdt.c189 panic("Max number of supported reserved-memory regions reached."); in process_reserved_memory_node()
229 panic("node %s missing `reg' property\n", name); in process_multiboot_node()
232 panic("fdt: node `%s': `reg` property length is too short\n", in process_multiboot_node()
410 panic("No valid device tree\n"); in boot_fdt_info()
A Dplatform.c74 panic("Unable to initialize the platform\n"); in platform_init()
/xen/xen/arch/x86/guest/hyperv/
A Dhyperv.c185 panic("Hyper-V hypercall percpu arg setup failed\n"); in setup()
188 panic("VP assist page setup failed\n"); in setup()
207 panic("Unable to reserve Hyper-V hypercall range\n"); in e820_fixup()
/xen/xen/arch/x86/pv/
A Ddom0_build.c111 panic("DOM0 P->M table overlaps initial mapping\n"); in setup_pv_physmap()
118 panic("Dom0 allocation too small for initial P->M table\n"); in setup_pv_physmap()
222 panic("Not enough RAM for DOM0 P->M table\n"); in setup_pv_physmap()
415 panic("Domain 0 expects too high a hypervisor start address\n"); in dom0_construct_pv()
495 panic("Domain 0 allocation is too small for kernel image\n"); in dom0_construct_pv()
504 panic("Not enough RAM for domain 0 allocation\n"); in dom0_construct_pv()
521 panic("Not enough RAM for domain 0 initrd\n"); in dom0_construct_pv()
821 panic("Not enough RAM for DOM0 reservation\n"); in dom0_construct_pv()
900 panic("Dom0 requires supervisor-mode execution\n"); in dom0_construct_pv()
/xen/tools/include/xen-external/
A Dbsd-sys-queue.h363 panic("Bad list head %p first->prev != head", (head)); \
370 panic("Bad link elm %p next->prev != elm", (elm)); \
375 panic("Bad link elm %p prev->next != elm", (elm)); \
479 panic("Bad tailq head %p first->prev != head", (head)); \
484 panic("Bad tailq NEXT(%p->tqh_last) != NULL", (head)); \
491 panic("Bad link elm %p next->prev != elm", (elm)); \
496 panic("Bad link elm %p prev->next != elm", (elm)); \
/xen/xen/arch/arm/arm64/
A Dtraps.c44 panic("bad mode\n"); in do_bad_mode()
/xen/xen/common/
A Dwarning.c14 panic("Too many pieces of warning text\n"); in warning_add()
/xen/xen/drivers/passthrough/x86/
A Diommu.c131 panic("Presently, iommu must be enabled for PVH hardware domain\n"); in arch_iommu_check_autotranslated_hwdom()
134 panic("PVH hardware domain iommu must be set in 'strict' mode\n"); in arch_iommu_check_autotranslated_hwdom()
/xen/xen/arch/x86/
A Dtraps.c761 panic("FATAL TRAP: vec %u, %s[%04x]%s\n", in fatal_trap()
774 panic("FATAL RESERVED TRAP: vec %u, %s[%04x]\n", in do_reserved_trap()
880 panic("FATAL TRAP: vector = %d (%s)\n" in do_trap()
1161 panic("Xen BUG at %s%s:%d\n", prefix, filename, lineno); in do_invalid_op()
1176 panic("Assertion '%s' failed at %s%s:%d\n", in do_invalid_op()
1188 panic("FATAL TRAP: vector = %d (invalid opcode)\n", TRAP_invalid_op); in do_invalid_op()
1538 panic("FATAL PAGE FAULT\n" in do_page_fault()
1658 panic("GENERAL PROTECTION FAULT\n[error_code=%04x]\n", regs->error_code); in do_general_protection()
1994 panic("CONTROL-FLOW PROTECTION FAULT: #CP[%04x] %s\n", ec, err); in do_entry_CP()
A Dmpparse.c247 panic("Recompile kernel with bigger MAX_IO_APICS\n"); in MP_ioapic_info()
267 panic("Max # of irq sources exceeded\n"); in MP_intsrc_info()
872 panic("Recompile kernel with bigger MAX_IO_APICS\n"); in mp_register_ioapic()
971 panic("Max # of irq sources exceeded\n"); in mp_override_legacy_irq()
1037 panic("Max # of irq sources exceeded\n"); in mp_config_acpi_legacy_irqs()
A Dsetup.c757 panic("Error creating domain 0\n"); in create_dom0()
801 panic("Could not construct domain 0\n"); in create_dom0()
973 panic("dom0 kernel not specified. Check bootloader configuration\n"); in __start_xen()
1075 panic("Bootloader provided no memory information\n"); in __start_xen()
1127 panic("Bootloader didn't honor module alignment request\n"); in __start_xen()
1400 panic("Not enough memory to relocate the dom0 kernel image\n"); in __start_xen()
1409 panic("Not enough memory to relocate Xen\n"); in __start_xen()
1736 panic("Error %d setting up IRQ data\n", ret); in __start_xen()
1881 panic("Could not protect TXT memory regions\n"); in __start_xen()
1907 panic("Could not set up DOM0 guest OS\n"); in __start_xen()
/xen/xen/xsm/
A Dsilo.c97 panic("SILO: Unable to register with XSM\n"); in silo_init()
/xen/xen/include/asm-arm/
A Dtraps.h31 panic("Guest Bug: %pv: '%s', line %d, file %s\n", \
/xen/xen/drivers/passthrough/vtd/
A Ddmar.h122 panic("DMAR hardware malfunction\n"); \
/xen/docs/misc/
A Dxen-error-handling.txt59 5. panic()
63 no extra diagnostic information such as a backtrace. panic() is

Completed in 48 milliseconds

123